Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Year range
1.
Rev. argent. endocrinol. metab ; 55(2): 41-50, jun. 2018. graf
Article in Spanish | LILACS | ID: biblio-1041735

ABSTRACT

RESUMEN Diversos estudios bioquímicos adicionales a la evaluación de Testosterona total (TT), biodisponible (Tbio) y libre (TL) han sido realizados a los efectos que pudieran resultar de mayor utilidad para el diagnóstico de patologías concomitantes en el SOP, entre otros. En la hormona anti Mülleriana, cuando la concentración supera a los 3,0 ng/ml existen evidencias de que el 79% de las mismas pueden ser identificadas correctamente como SOP. El Antígeno Prostático Específico (PSA), marcador de singular importancia en pacientes con cáncer de Próstata, con técnicas ultrasensibles ha podido ser detectado en más del 50% en mujeres. En un grupo de pacientes con SOP, los niveles circulantes de PSA fueron significativamente mayores que en las mujeres sin SOP. El Kiss-1 aislado de la placenta y demostrado en otros tejidos, presenta niveles aumentados que correlacionan con la LH, TT, TL y resistencia a la insulina (RI) en adolescentes con SOP versus adolescentes sin SOP, sugiriendo que el Kiss-1 podría estar involucrado en el desarrollo del SOP en estas pacientes. Algunas pacientes con SOP están asociadas a patologías relevantes, de las cuales han sido comunicadas el aumento del BMI, mayor grado de dislipemia, adiposidad central, RI y Síndrome Metabólico (SMe). En las pacientes con un fenotipo clásico (hiperandrogenismo, alteración del ciclo menstrual y ovarios poliquísticos), estas patologías son de mayor frecuencia y severidad que en los otros fenotipos, particularmente aquellos sin hiperandrogenismo. Otras determinaciones como TNFα, interleuquinas, test de tolerancia a la glucosa, ApoB, partículas pequeñas de LDL e Inhibidor del Activador del Plasminógeno-1 han sido comunicados que podrían ser de utilidad para tener mayor sensibilidad en la definición de patología concomitantes en el SOP. Actualmente se ha comenzado a evaluar otros marcadores como el Fetuin-A; Quemerina, Nesfatina-1, Neopterina y Endocannabinoides, cuyos resultados preliminares parecerían ser un aporte importante para evaluar SMe y RI en paciente con SOP y tratar de definir su prevalencia en los distintos fenotipos de esta patología.


ABSTRACT Several biochemical studies in addition to the evaluation of total Testosterone (TT), bioavailable (bioT) and free (FT) have been performed to the effects that could be of greater use for the diagnosis of concomitant pathologies in the PCOS, among others. The anti-Müllerian hormone whose concentration when exceeds 3.0 ng/ml, there is evidence that 79% of these patients can be correctly identified as PCOS. The Prostate-Specific Antigen (PSA), a marker of singular importance in patients with prostate cancer, with ultra-sensitive techniques, has been detected in more than 50% of women. In a group of patients with PCOS, circulating levels of PSA are significantly higher than in women without PCOS. The Kiss-1 isolated from the placenta and demonstrated in other tissues, has increased levels that correlate with LH, TT, TL and insulin resistance (IR) in adolescents with PCOS respect to adolescents without PCOS, suggesting that Kiss-1 could be involved in the development of the PCOS in these patients. In some patients with PCOS, they are associated with relevant pathologies, of which the increase in BMI, higher degree of dyslipidemia, central adiposity, IR and Metabolic Syndrome (MeS) have been reported. Those that show a classic phenotype (hyperandrogenism, alteration of the menstrual cycle and polycystic ovaries) these characteristics are of greater frequency and severity than in the other phenotypes, particularly those without hyperandrogenism. Other determinations such as TNFα, interleukins, glucose tolerance test, ApoB, small particles of LDL and Plasminogen Activator Inhibitor-1 have been reported that could be useful to have greater sensitivity in the definition of concomitant pathology in the PCOS. Currently, other markers such as Fetuin-A, Chemerin, Nesfatin-1 Neopterin and Endocannabinoids have been evaluated. The preliminary results suggest to be an important contribution to define MeS and IR in patient with PCOS and to try to determine its prevalence in the different phenotypes of this pathology.


Subject(s)
Humans , Female , Polycystic Ovary Syndrome/complications , Polycystic Ovary Syndrome/physiopathology , Biomarkers/analysis , Polycystic Ovary Syndrome/blood , Metabolic Syndrome/complications , Dyslipidemias/complications , Androgens/analysis
2.
Rev. argent. endocrinol. metab ; 55(1): 43-56, mar. 2018. graf.
Article in Spanish | LILACS | ID: biblio-1248114

ABSTRACT

Esta revisión fue realizada con el fin de evaluar nuestros resultados de laboratorio así como aquellos de la literatura que constituyen, a nuestro entender, aportes significativos en el síndrome de ovarios poliquísticos (SOP). Nuestro especial énfasis será presentar las limitaciones de las metodologías empleadas por nuestro grupo, comparativamente a las reportadas por otros investigadores. La determinación de andrógenos, en particular de Testosterona (TT), es quizá la de mayor complejidad dado que los resultados con los diferentes inmunoensayos empleados en nuestro medio producen resultados muy variables por los diferentes métodos y aún entre laboratorios que usan la misma metodología. La técnica de referencia es la cromatografía líquida en tándem con espectrometría de masa (LC-MSMS), de difícil aplicación en laboratorios de análisis clínicos debido a su alto costo y la imposibilidad de resolver numerosas muestras. En estudios previos demostramos que de los métodos habitualmente usados para evaluar la TT circulante, solo en 2 inmunoensayos los resultados obtenidos fueron satisfactoriamente validados indirectamente según el criterio del Consenso de los Centros para el Control y Prevención de Enfermedades (CDC, USA) contra LC-MSMS, los cuales fueron comparables a dicha metodología con niveles superiores a 0,5 ng/ml. El SOP puede presentar factores de riesgo aumentados para la enfermedad cardiovascular y la diabetes II. Estos factores no están debidamente categorizados en función de los distintos fenotipos del SOP. Se evaluarán los principales analitos empleados con este objetivo y los nuevos que aporten elementos de mayor especificidad en este sentido


This review was performed in order to evaluate our laboratory results as well as those of the literature that constitute, in our opinion, significant contributions in these pathophysiologies. Our special emphasis will be on presenting the limitations of the methodologies used by our group, compared to those reported by other researchers. The determination of androgens, in particular Testosterone (TT), is perhaps the most complex since the results with the different immunoassays used in our environment produce very variable results by the different methods and even between laboratories that use the same methodology. The reference technique is LC-MSMS, difficult to apply in clinical analysis laboratories because of its high cost and the inability to solve numerous samples. In previous studies, we demonstrated that, in comparison to LC-MSMS with the usual methods for evaluating circulating TT, the results obtained in only 2 immunoassays were satisfactorily validated indirectly according to the criteria of CDC against LC-MSMS, which were comparable to that methodology with levels higher than 0.5 ng/ml. PCOS may have increased risk factors for cardiovascular disease and diabetes II. These factors are not properly categorized according to the different phenotypes of PCOS. The main analytes used for this purpose will be evaluated and new ones that contribute elements of greater specificity in this sense


Subject(s)
Humans , Female , Polycystic Ovary Syndrome/etiology , Polycystic Ovary Syndrome/physiopathology , Testosterone/analysis , Phenotype , Mass Spectrometry/methods , Immunoassay/methods , Chromatography, Liquid/methods
3.
Rev. argent. endocrinol. metab ; 52(3): 137-152, jun. 2015. graf, tab
Article in Spanish | LILACS | ID: biblio-957925

ABSTRACT

Objective: To compare normal and hirsute women Testosterone (T) measurements performed at different laboratories by the same or different methods, and the gold standard method LC-MS/MS (Quest Diagnostics, USA). Design: Prospective study. Setting: Hormone Determination Laboratory, Hospital Italiano, La Plata, and each participating laboratory's private practice. Patient(s): Blood samples were obtained from 23 individuals sorted into two groups, namely, normal women, n: 11(NW) and hirsute women, n: 12 (HW). Interventions(s): None. Main Outcome Measure(s): To evaluate whether serum T measurements obtained from each serum by the methods currently employed in our country, some of whose kits exhibit changes in previous presentations, some LC-MS/MS-validated and other non-validated ones are significantly different from those obtained by LC-MS/MS. Result(s): None of the 11 NW showed high T values by LC-MS/MS. Two out of the 12 hirsute patients showed normal T values (LC-MS/MS). Methods and number of participating labs -shown between brackets were: in NW, 1st generation Architect (1), 2nd generation Architect (1); Immulite (1) Cobas (4); Access (1); Centaur (2); Immunotech-RIA (1); and, in HW, 2nd generation Architect (3); Immulite (3); Cobas (4); Access (1); Centaur (2); Immunotech-RIA (1). No false positives resulted from the assays performed. No lab yielded false positive results in the NW group. No false positives were reported from the 10 hirsute women with increased T values by LC-MS/MS. False positives, though, resulted from two female hirsute patients with normal T values studied by four of the methods. Statistically, the serum T measurements obtained were significantly different by Centaur in NW and, in HW, by Immulite and Centaur as compared to LC-MS/MS. In the Bland-Altman plot, Centaur and Cobas showed over 5 % of measurements outside the limits of agreement in the HW group. Assessment by p-Spearman resulted in divergences with LC-MS/MS for all methods in NW, whereas in the HW group there were none. When estimating sampling bias for each laboratory taking LC-MS/MS as the reference method and adopting a ± 6.4 % mean bias acceptability criterion for each method compared to LC-MS/MS, two of the techniques reviewed, 2nd generation Architect and Cobas, met the validation requirement satisfactorily. However, one lab out of three using 2nd generation Architect failed to meet the validation requirement, while two out of four labs using Cobas also failed to meet the requirement. This demonstrates the great variability among methods, even when labs are employing the same technique. Conclusion: From the clinical point of view, the methods currently used in our local environment yielded no false positives or false negatives and therefore did not misdiagnose hyperandrogenism. Still, Immulite, Centaur, RIA and Access did present false positives in two of the T-normal hirsute women. The relation of serum T measurements obtained by each method to measurements obtained by LC-MS/MS reveals that the dispersion of the results was larger with values under 0.3 ng/ml, quite close to the detection limit of the various techniques.


Objetivos: Comparar los resultados de testosterona (T) obtenidos en diferentes laboratorios en mujeres normales (MN) e hirsutas (MH), empleando el mismo o diferentes métodos respecto a la técnica de cromatografía líquida en tándem con espectrometría de masa LC-MS/MS (gold standard) realizada en el laboratorio Quest (USA) Protocolo: Estudio prospectivo Estudio realizado en: Laboratorio de Determinaciones Hormonales; Hospital Italiano de La Plata y en los laboratorios privados de cada participante Pacientes: Se obtuvieron muestras de sangre periférica en 23 mujeres agrupadas en 2 grupos: controles normales (n:11) y en mujeres hirsutas (n: 12) Intervención: Ninguna. Principales resultados a evaluar: Evaluar si con los métodos habituales empleados en nuestro medio con los diferentes kits comerciales, de los cuales algunos han sido convalidados por técnica "gold standard" y otros no, presentan diferencias significativas con los obtenidos por LC-MS/MS Resultados: Los resultados obtenidos por LC-MS/MS mostraron que ninguna de las 11 MN tuvieron niveles aumentado de T y 2 MH tuvieron valores normales de T. Los métodos empleados y el número de laboratorios (entre paréntesis) que emplearon cada método fueron en MN Architect 1st generation (1) Architect 2nd generation (1); Immulite (1); Cobas (4); Access (1); Centauro (2); Immunotech-RIA (1). En las MH Architect 2nd generation (3); Immulite (3); Cobas (4); Access (1); Centauro (2); Immunotech-RIA (1). En el grupo de MN en ningún laboratorio (lab) se obtuvieron resultados falsos positivos. En el grupo de MH no se obtuvieron falsos negativos en las 10 hirsutas con valores aumentados de T por LC-MS/MS. En las 2 pacientes hirsutas con T normal en 4 métodos se obtuvieron falsos positivos Estadísticamente los resultados fueron significativamente diferentes, en las MN por Centauro y en las MH por Immulite y Centauro. En el análisis de Bland-Altman Centauro y Cobas en las MH presentaron más del 5 % de los resultados fuera del límite de acuerdo. Resultados por p-Speerman todos los métodos fueron diferentes a LC-MSMS en las MN y no se obtuvieron diferencias en el grupo de MH. Evaluando el bias de cada muestra en cada laboratorio respecto a LC-MS/MS y adoptando el criterio de aceptabilidad de ± 6,4 % mean bias de cada método respecto al de LC-MS/MS, 2 de las metodologías estudiadas, Architect 2da generación y Cobas pasaron satisfactoriamente el requisito de validación, sin embargo de los 3 laboratorios que emplearon 2da generación, 1 no pasó el criterio de validación y de los 4 que usaron Cobas, 2 tampoco lo pasaron. Esto demuestra la gran variabilidad de los métodos aun entre lab que emplean la misma técnica. Conclusiones: Desde el punto de vista clínico los métodos habitualmente empleados en nuestro medio, no sobrediagnosticaron o subdiagnosticaron hiperandrogenismo, por no presentar falsos positivos o negativos respectivamente. Sin embargo Immulite, Centauro, RIA y Access presentaron falsos positivos en las 2 hirsutas con T normal. En la relación de los resultados de cada muestra en cada método sobre el valor de LC-MS/MS referido a la concentración de T en ese suero por LC-MS/MS, la mayor dispersión de los resultados se observaron con valores menores de 0,3 ng/ml, muy cercano al límite de detección de las diferentes técnicas.

4.
Rev. argent. endocrinol. metab ; 50(1): 3-18, Apr. 2013. ilus, tab
Article in English | LILACS | ID: lil-694884

ABSTRACT

Objective: To compare T results in normal and hirsute women, obtained by different laboratories employing the same or different methods, including an in-home RIA, and the gold standard method LC-MS/MS. In addition, T results were referred to a curve obtained by 6 different pools that had been prepared on the basis of LC-MS/MS results. Design: Prospective study Setting: Hormone Determination Laboratory, Hospital Italiano, La Plata, and private practice of each participant laboratory. Patient(s): Blood samples were obtained from 78 individuals sorted into 3 groups, namely, normal men (n:39), normal women (n:24) and hirsute women (n:15) Interventions(s): None Main Outcome Measure(s): To evaluate if the results obtained in each lab for each serum sample by the methods currently employed in our country are significantly different from those obtained by LC-MS/MS (Gold standard) Result(s) One out of the 24 NW showed high T values by LC - MS/MS. In each lab, except in 1 (Architect) T results of this serum sample were normal. Two out of the 15 hirsute patients showed normal T values (LC - MS/MS). Method and number of labs -shown between brackets- and percentages of normal T results (false negatives) are described for each method as follows: Chemiluminescence: Axsym - Abbott (Axn) - (3) 85, Architect - Abbott - (Arch); (2) 70; Immulite - Siemmens - (IMM); (2) 42; Electrochemiluminescence - Elecsys - Roche- ((EQL); (4) 52; Fluorescent enzymatic - Vidas - Bio-Merieux - (Vidas) (1) 69; Manual coated tube radioimmunoassay (RIA): RIA - Siemmens Coat-a-Count (RIA S); (3) 64; RIA - DSL Inc (RIA DSL); (1) 31; RIA - DIASource - (DiaS); (1) 31; and in-Home RIA (in-H) (1) 12. Statistically significant differences were obtained between different methods and against LC MS/MS. In-H method is the one that comes closest to 1 on the Weighted Deming regression and closest to zero on the SD intercept, (standard deviation of the constant in the straight line equation) indicating that the values match those obtained by LC - MS/MS. The values recorded by the various methods employed showed no significant modifications when plotted against a secondary standard curve. Conclusion(s) This indicates that the techniques in current use in our area underestimate hyperandrogenemia in these patients. Discrepancies are not due to the various calibration curves proposed in the corresponding commercial kits. The fact that the In-H technique affords finer results while employing a larger serum volume suggests that the disparities among the various commercial methods result from their limited sensitivity to the sample volumes they process.


El diagnóstico de hiperandrogenemia requiere la demostración de niveles aumentados de Testosterona Total (TT) en suero. Los inmuno ensayos comerciales dan resultados divergentes a niveles bajos de TT como los obtenidos en mujeres. Valoramos los niveles de TT en 24 mujeres normales (MN) y 15 hirsutas (MH) en 18 laboratorios por métodos comúnmente empleados en nuestro medio. Los métodos y número de laboratorio que emplearon cada método se muestra entre paréntesis así como los porcentajes de T normal (falsos negativos) obtenidos en cada método fueron: Quimioluminiscencia: Axsym - Abbott (Axn)- (3) (85), Architect - Abbott - (Arch); (2) 70; Immulite - Siemmens - (IMM); (2) 42; Electroquimioluminiscencia - Elecsys - Roche- ((EQL); (4) 52; Enzimático acoplado a fluorescencia Vidas - Bio-Merieux - (Vidas) (1) 69, Radioinmunoiensayo en tubo recubierto (RIA): RIA - Siemmens (RIA S); (3) 64; RIA - DSL Inc (RIA DSL); (1) 31; RIA - DIASource - (DiaS); (1) 31; y un método desarrollado en uno de los laboratorios (in-H) (1) 12. Comparativamente a LC MS/MS los niveles fueron en todas las muestras significativamente más bajos por Axn y en 18 de las 24 MN por DiaS. En 7 casos; 3 por RIA S, 2 por IMM y 1 por EQL y Arch los valores de TT fueron superiores al límite superior de sus respectivos métodos. En todos los casos se obtuvo una gran variación entre los mismos y con diferentes métodos. Trece de las 15 MH tuvieron niveles altos de TT por LC MS/MS. De las MH con TT aumentada de acuerdo a la determinación por LC MS/MS entre el 12 y el 85 % de las mismas por los distintos métodos fueron normales, indicando que en la mayoría de los métodos habitualmente utilizados en nuestro medio subvaloran la hipernadrogenemia en estas pacientes. Estas diferencias se hacen más notorias a niveles más bajos de TT (Se obtuvieron valores normales en el 71 % de los casos con valores de TT entre 0,47 y 0,74 ng/ml y en el 38 % de los casos, con niveles de TT mayor a 0,98 ng/ml). ...

SELECTION OF CITATIONS
SEARCH DETAIL